Search results for " evaporative cooling"
showing 9 items of 9 documents
Numerical evaluation on performances of AHU equipped with a cross flow heat exchanger in wet and dry operation
2012
Abstract In this paper the comparison between the performance of a cross flow heat exchanger in wet and dry operation for air handling process has been investigated. In addition, a case study of application of the component to perform indirect evaporative cooling in a AHU was studied with the software TRNSYS.Using experimental data and an appropriate analytical method, energy saving performances of the system has been evaluated through the entire cooling season for a typical Mediterranean site. Results show that high energy saving potential can be obtained if the component is operated in wet operation in term of reduction of electricity consumption.
Energy performance improvements of a DEC system due to wet heat exchangers
2011
This work concerns an innovative desiccant and evaporative cooling (DEC) system for building air conditioning. The original system is an experimental DEC air handling unit installed at the Solar Laboratory of the University of Palermo and recently modified and updated. With the aim to increase the cooling effect due to water evaporation in the return air flow rate, the sensible heat exchanger was replaced with two cross flow flat plate heat exchangers installed in series, with continuous humidification of the secondary air flow. The new thermodynamic cycle is theoretically described and the realization of the real application is shown. Detailed operational data and energy performance indica…
Energy performance evaluation of a demo solar desiccant cooling system with heat recovery for the regeneration of the adsorption material
2012
Abstract Since July 2008, a Solar Desiccant Evaporative Cooling (DEC) system has been operating as a test plant at the solar laboratory of the Dipartimento di Energia (ex DREAM) of the University of Palermo. The system is composed of an air handling unit (AHU) designed for ventilation of the laboratory coupled with a radiant ceiling that provides most of the required sensible cooling/heating energy. Flat plate collectors deliver part of the regeneration heat of the desiccant wheel during the summertime and are used for space heating during the wintertime. The system was designed for high humidity loads because of the typical climate conditions at the site and the need to support a radiant c…
FREESCOO facade 3.0, a compact DEC thermally driven air-conditioning system for apartments
2020
FREESCOO is an innovative Desiccant Evaporative Cooling air conditioning system designed for ventilation, cooling, dehumidification and heating of buildings in residential and tertiary sectors. This paper presents the third generation of the façade version, which will be tested on field in Milan (Italy) within the Merezzate+ project supported by Climate-KIC. The adsorption bed used by the system is a finned heat exchanger packed with silica gel grains, which allows simultaneous dehumidification and cooling of the process air. The direct evaporative cooling process, operated downstream to the dehumidification, is realized using a rotary plate humidifier. The regeneration of the adsorption be…
A brine evaporative cooler/concentrator for autonomous thermal desalination units
2011
In recent years growing attention has been paid to the problem of brine disposal due to the raising awareness of significant environmental issues related to the use of desalination processes for fresh water production. This is particularly relevant when desalination units are located in remote sites, characterised by major complexity in the construction and management of intake and outfall structures. In the present work a novel device, named brine evaporative cooler/concentrator (BECC, patent pending), has been developed for coupling with small-scale thermal desalination plants in order to reduce the problem of brine disposal. Such device fulfils two different functions: i) cooling of the …
Quality Assurance and Support Measures for Solar Cooling on System Level
2016
Abstract Within the IEA SHC Task 48 “Quality assurance and support measures for Solar Cooling” the analysis and evaluation of the systems has been one of the four main focuses. Here the activities are including the lab- and field-based characterization of the systems, the definition and application of performance figures, a guideline for a reliable monitoring procedure including methods for automated error detection and an updated overview on worldwide installed DEC systems including hints and good practice examples. They are furthermore leading to three different easy-to-use tools for solar cooling systems: The LCA tool considers environmental and energetic values for the evaluation, the P…
Natural Convection Cooling of a Hot Vertical Wall Wet by a Falling Liquid Film
2008
Abstract The system studied is a plane channel in which one of the two vertical walls is kept at an arbitrary temperature profile and may be partially or completely wet by a falling liquid film, while the opposite wall is adiabatic. Air from the environment flows along the channel with a mass flow rate which depends on the balance between hydraulic resistances and buoyancy forces. These latter, in their turn, depend on the distribution of temperature and humidity (hence, density) along the channel and eventually on the heat and mass transferred from wall and film to the humid air. A simplified computational model of the above system was developed and applied to the prediction of relevant qu…
ADVANCED SOLAR ASSISTED DESICCANT AND EVAPORATIVE COOLING SYSTEM EQUIPPED WITH WET HEAT EXCHANGERS
2011
Abstract This work concerns an innovative solar assisted desiccant and evaporative cooling (DEC) system for building air conditioning. In this system, air-to-air packaged wet heat exchangers are used to maximize the exploitation of the evaporative cooling potential associated with the exhaust air stream. The thermodynamic cycle is first theoretically described, and then an example of a real application is shown. The system presented is an experimental DEC system originally installed at the beginning of 2008 at the Solar Laboratory of the University of Palermo and recently modified and updated. These modifications have been implemented with the aim to foster some problems related to the conv…